DESCRIPTION ALCO Tri-County
Trowel-On is a heavy bodied, non-asbestos fiber filled, solvent based
dampproofing that can be troweled to exterior surfaces of concrete or
masonry walls below grade.
USE Ideal
when maximum dampproofing is needed for reducing dampness and moisture infiltration through foundation walls,
footings, retaining walls, tanks, culverts and bridge abutments.
ADVANTAGES »
Easy
Application - Use Standard Trowel » Ready to
Use » Fast and economical way to protect concrete and
masonry foundations from moisture penetration
PREPARATION The surface being coated must be clean, dry and
free from oil, form release agents and any foreign matter such as dust,
dirt, etc. Be sure all voids, cracks and rod holes are repaired with ALCO
24/7 Flashing Cement and a fabric membrane, when needed. This material
will span small hairline cracks, but all voids and crevices must be
repaired before application. Large voids and crevices in concrete should
be filled with mortar cement and allowed to cure completely.
APPLICATION
With a standard trowel, apply at the rate of 1/8" film or 12.5
SF/Gallon. If two coats are needed and a fabric membrane is used, imbed
fabric membrane into mastic, overlapping edges 3 - 4 inches and press
firmly in place. Let first coat cure before applying second coat. COLD
WEATHER APPLICATION: For best coverage results, material should be stored
in a warm warehouse and applied at the temperature of 40° F. or
above.
This product is formulated in three grades to accommodate seasonal
temperature ranges.
Summer
65 - 95 + 5 Degrees
Spring/Fall
40 - 65 + 5 Degrees
Winter
24 - 40 + 5 Degrees
APPROXIMATE COVERAGE 1/8"
Film
12.5 SF/Gallon
1/4"
Film
6.25 SF/Gallon
SPECIFICATION ASTM D-4586, Type
I
VOC
Not to Exceed: 300 g/L 2.5 Lbs/Gal
FOR OUTDOOR USE ONLY
DO NOT THIN THIS PRODUCT
SECURE COVER WHEN NOT IN USE
PACKAGING
5 Gallon Pail
36/Pallet 55 Gallon Drum 4/Pallet
LIMITATIONS *
Not for use on wood * For professional use
only * Being a solvent based material, some insulation boards
may not be compatible. Check with board manufacturer before
applying.
PROPERTIES Flash Point (ASTM
D-93-99): 100° F. Minimum
Weight per Gallon (Approximate): 8.73 Lbs
Non-Volatile (Fed Test Method 141): 62% Minimum
Percent of Specially Processed Asphalt: 58% Minimum
Percent of Total Solids, by Volume: 58% Minimum
Film Thickness of 1 Gal/12.5 SF: 1/8"
Drying Time: 2 -3 Days
Service Temperature, Extended Exposure: -30° to 150° F.
Resistance to Oils & Solvents: Poor
Resistance to Sunlight: Good
Resistance to Chemicals: Good
Effect of Weathering: Slight Chalking
Resistance to Water:
Under Good Drainage Conditions:
Excellent
Under Continuous Submersion:
Not Recommended
FOR FURTHER SAFETY
INFORMATION SEE MSDS REGARDING THIS PRODUCT
PRECAUTIONS Caution Combustible Contains Petroleum
Distillates Hazard Rating: Health
- 1 Fire - 2 Reactivity -
0
(0 = Least; 4 = Extreme)
Respiratory: Use with adequate ventilation. Inhalation of high vapor
concentration may cause headaches and/or dizziness. NIOSH/MSHA Respirators
required if TLV is exceeded. Personal Protection: Avoid prolonged or repeated
contact with skin, which may cause irritation. Chemical resistant gloves
such as neoprene are recommended. Do not get in eyes; splash proof goggles
are recommended. Wear protective clothing if needed. Do not take
internally. Fire Protection: Keep away from heat, open flame or
any source of ignition. First Aid: Eye Contact - Rinse
immediately with water for 15 minutes and seek medical
advice. Skin Contact - Wash thoroughly with soap and water. Inhalation
- Remove individual to fresh air. If breathing is difficult, administer
oxygen. If breathing has stopped, give artificial respiration; get medical
attention immediately. Ingestion - Do
not induce vomiting. Get medical attention immediately. Waste
Disposal: Seal container when not in use. Empty containers must be
disposed in an approved landfill in accordance with local, state and
Federal regulations.
Spill or Leak: Shut off ignition source; no open flame. Stop leak
without risk. Dike area of spill and take up with sand or other suitable
material. Prevent from entering drains, sewers or waterways.
KEEP OUT OF REACH OF CHILDREN!
WARRANTY
We warrant our materials to be of good quality and will
replace materials found defective, providing, however, that the buyer
shall examine the materials when received and promptly notify us of any
defects before the materials are used or incorporated into a structure for
which they are intended. Unless otherwise agreed to in writing, this
warranty shall extend only to comply with specifications of materials
manufactured by and published by ALCO-NVC Inc., and made available to the
buyer at request. We cannot warrant nor in any way guarantee particular
methods, use or applications, nor can we warrant that the materials will
be suitable for any intended use. This warranty is in lieu of all others
expressed or implied and may not be extended by representatives, written
sales or information or drawings. Nor do our distributors or salesmen or
any other representatives of distributors or of this company have
any authority to extend any guarantee beyond that outlined above or to
waive the limitations of the seller's liability.
Give us a call at (800)
323-0029, we'll tell you even more!

ALCO-NVC Inc.
580
St. Jean Detroit, MI 48214-0001 Toll Free: (800)
323-0029 Fax: (313)
331-4726
HOME | ABOUT US |
PRODUCTS | SYSTEMS |
MSDS | CONTACT | REQUEST
© ALCO NVC, INC. ALL RIGHTS RESERVED. WEB SITE BY: DIVERSIFIED