DESCRIPTION ALCO Asphalt Roof Primer
is a rapid cure, general purpose primer used for the preparation of all
types of surfaces prior to the application of hot or cold asphalt
coatings. It is of thin consistency, which can be used over several types
of surfaces.
USE : All purpose
primary coat for concrete, masonry block, brick, gypsum and metal
substrates which will later be coated with an asphaltic product :
Rejuvenates old, dried out built-up roofs where penetration is required to
revitalize the base surface
ADVANTAGES »
Easy application - Brush or Spray » No heating or
thinning » Rapid Cure » Ready to use from the
container
PREPARATION All surfaces to be primed or coated with Asphalt
Primer must be clean, dry and free of debris, oil, grease and other
foreign matter.
APPLICATION
Material can be used directly from the container by either brush or
spray. Dried out built up roofs and masonry surfaces should be generously
coated to obtain the maximum saturation so that an effective bond can and
may be achieved for the covering material.
If the first coat becomes completely absorbed, apply a second coat. Drying
time will depend on the mil thickness of application. If faster cure is
needed, a mist coat is recommended.
NOTE: The thinner the application, the faster this material will cure. For
best results, this material should be used at temperatures above 40° F.
COVERAGE 75 - 100 SF/Gallon
Depending on Porosity of Surface
SPECIFICATION ASTM D-41
VOC
Not to Exceed: 500 g/L 4.0 Lbs/Gal
FOR OUTDOOR USE ONLY
DO NOT THIN THIS PRODUCT
SECURE COVER WHEN NOT IN USE
PACKAGING
17.25 Oz Spray Can 12/Carton
1 Gal
Can
6/Carton
5 Gallon Pail
36/Pallet 55 Gallon Drum
4/Pallet
LIMITATIONS *
Do not use on wood * Do not use on roofs previously
coated with Coal Tar * For professional use
only * Previous use of wax/resin curing compound on a concrete
deck may inhibit bonding * May not be compatible with some
one-ply systems. Check manufacturer of roof system before
application
PROPERTIES Flash Point (ASTM
D-93): 100° F. +
Weight per Gallon (Approximate): 7.2 Lbs
Viscosity @ 77° F. (ASTM D-88): 25 - 125 SSF
Non-Volatile (Fed Test Method 141): 50% +
Percent of Specially Processed Asphalt: 50% +
Percent of Total Solids, by Volume: 40% +
Film Thickness of 1 Gal/100 SF (Less Absorption by Surface): 1/64"
Drying Time: 1 - 2 Days
Service Temperature, Extended Exposure: Ambient
Resistance to Oils & Solvents: Poor
Resistance to Sunlight: Good
Resistance to Chemicals: Good
Effect of Weathering: Poor
Resistance to Water:
Under Good Drainage Conditions:
Excellent
Under Continuous Submersion:
Not Recommended
FOR FURTHER SAFETY
INFORMATION SEE MSDS REGARDING THIS PRODUCT
PRECAUTIONS Caution Combustible Contains Petroleum
Distillate Hazard Rating: Health
- 1 Fire - 2 Reactivity -
0
(0 = Least; 4 = Extreme)
Respiratory: Use with adequate ventilation. Inhalation of high vapor
concentration may cause headaches and/or dizziness. NIOSH/MSHA Respirators
required if TLV is exceeded. Personal Protection: Avoid prolonged or repeated
contact with skin, which may cause irritation. Wear chemical resistant gloves. Do not get in eyes;
wear protective goggles. Wear protective clothing if needed. Do not take
internally. Fire Protection: Keep away from heat, open flame or
any source of ignition. First Aid: Eye Contact - Rinse
immediately with water for 15 minutes and seek medical
advice. Skin Contact - Wash with soap and water. Inhalation
- Remove individual to fresh air. If breathing is difficult, administer
oxygen. If breathing has stopped, give artificial respiration; get emergency
medical
attention and keep victim warm. Ingestion - Do
not induce vomiting. Get medical attention immediately. Waste
Disposal: Seal container when not in use. Empty containers must be
disposed in an approved landfill in accordance with local, state and
Federal regulations.
KEEP OUT OF REACH OF CHILDREN!
WARRANTY
We warrant our materials to be of good quality and will
replace materials found defective, providing, however, that the buyer
shall examine the materials when received and promptly notify us of any
defects before the materials are used or incorporated into a structure for
which they are intended. Unless otherwise agreed to in writing, this
warranty shall extend only to comply with specifications of materials
manufactured by and published by ALCO-NVC Inc., and made available to the
buyer at request. We cannot warrant nor in any way guarantee particular
methods, use or applications, nor can we warrant that the materials will
be suitable for any intended use. This warranty is in lieu of all others
expressed or implied and may not be extended by representatives, written
sales or information or drawings. Nor do our distributors or salesmen or
any other representatives of distributors or of this company have
any authority to extend any guarantee beyond that outlined above or to
waive the limitations of the seller's liability.
Give us a call at (800)
323-0029, we'll tell you even more!

ALCO-NVC Inc.
580
St. Jean Detroit, MI 48214-0001 Toll Free: (800)
323-0029 Fax: (313)
331-4726
HOME | ABOUT US |
PRODUCTS | SYSTEMS |
MSDS | CONTACT | REQUEST
© ALCO NVC, INC. ALL RIGHTS RESERVED. WEB SITE BY: DIVERSIFIED