DESCRIPTION ALCO Alumagard
Non-Fibered Aluminum Roof Coating consists of a high quality oxidized
cutback asphalt and premium quality aluminum pigments which flake and
float to the surface upon application. The thin consistency allows for
easy application.
USE : Excellent over metal roofs :
Recommended for asphalt roofs and Modified Bitumen Membrane
ADVANTAGES » Lowers surface temperature of roof by as
much as 15° F. » Can turn away over 70% of harmful UV
rays » Easy Application » Excellent
Coverage » Economical » Premium 3#
performance » UL Approved » FM Approved
» Energy Star Partner
PREPARATION The roof surface must be completely dry and free
of dirt, dust and debris before application. Be sure that all necessary
repairs are done to the roof surface. Metal surfaces must be wire brushed
and swept clean. This will ensure proper adhesion. In some cases ALCO
Primer may be advisable. Allow primer to dry for 24 hours before aluminum
application. ALCO 24/7 Flashing Cement can be used to repair flashing,
blisters or voids.
APPLICATION Use directly from the container. Mix contents
thoroughly to insure complete dispersion of aluminum pigments. DO NOT
THIN. Pour Alumagard Non-Fibered coating on roof, a little at a time, and
brush like any roof coating, brushing in one direction only. Over brushing
causes some of the aluminum sheen to lessen, resulting in inferior
reflective qualities.
For best results, apply on a warm (60° F), sunny day with no rain in the
forecast. The presence of moisture will create a rapid "browning
out". The warm temperatures will soften the asphalt content and allow
the aluminum pigments to rise to the surface for maximum reflectivity.
New asphalt roof surfaces should weather a minimum of 90 days before
applying Alumagard. However, Alumagard may be applied over ALCO emulsion
roof coatings after curing (between 5 - 10 days) without staining.
APPROXIMATE COVERAGE BUR:
75 - 150 SF/Gal
Metal: 125 - 200 SF/Gal
APP: 75 - 100 SF/Gal
SPECIFICATION ASTM D-2824, Type
I
VOC
Not to Exceed: 500 g/L 4.0 Lbs/Gal
FOR OUTDOOR USE ONLY
DO NOT THIN THIS PRODUCT
SECURE COVER WHEN NOT IN USE
PACKAGING
1 Gal
Can
6/Carton
5 Gallon Pail
36/Pallet 55 Gallon Drum 4/Pallet
LIMITATIONS *
Do not use over wood * Not compatible with roofs
coated with Coal Tar * For professional
use only * Will not adhere to wet or damp roof *
Do not use if rain is in the forecast * On new, single-ply
roofs, always check with the manufacturer of the roofing system for
compatibility with this product * Not recommended for ponded
water
PROPERTIES Flash Point (ASTM
D-93): 100° F. +
Weight per Gallon (Approximate): 8.5 Lbs
Viscosity @ 77° F. (ASTM D-2824): 20 - 30 KU
Percent of Asphalt: 25% +
Percent of Metallic Aluminum Leafing Paste: 26% +
Percent of Solids, by Weight: 30% Minimum
Type Aluminum Paste:
TT-P-320-D, Type II: Class 2
ASTM D-962, Type II: Class C
Insoluble in CS2, Maximum % of NVM: 40%
Non-Volatile Matter (NVM): 40% Minimum
Film Thickness of 100 SF/Gallon (Less Absorption by Surface): 1/64"
Reflectivity (ASTM Requirement): 50% +
Drying Time: Overnight
Service Temperature: -20° to 180° F.
Resistance to Solvents: Poor
Resistance to Chemicals: Poor
Resistance to Sunlight: Excellent
Effect of Weathering: Slow Erosion
Acid Rain & Corrosive Atmospheric Conditions
will Discolor or Darken
Resistance to Water:
Under Good Drainage Conditions:
Excellent
Under Continuous Submersion:
Not Recommended
FOR FURTHER SAFETY
INFORMATION SEE MSDS REGARDING THIS PRODUCT
PRECAUTIONS Caution Combustible Contains Petroleum
Distillates Hazard Rating: Health
- 1 Fire - 2 Reactivity -
0
(0 = Least; 4 = Extreme)
NOTE: DO NOT THIN. DO NOT MIX WITH WATER, ACIDS OR ALKALIS
Respiratory: Use with adequate ventilation. Inhalation of high vapor
concentration may cause headaches and/or dizziness. NIOSH/MSHA approved
respirators
required if TLV is exceeded. Personal Protection: Avoid prolonged or repeated
contact with skin, which may cause irritation. Wear chemical resistant gloves.
Do not get in eyes; wear protective goggles. Wear protective clothing if needed. Do not take
internally. Fire Protection: Keep away from heat, open flame and
any sources of ignition. First Aid: Eye Contact - Rinse
immediately with water for 15 minutes and seek medical
advice. Skin Contact - Wash with soap and water. Inhalation
- Remove individual to fresh air. If breathing is difficult, administer
oxygen. If breathing has stopped, give artificial respiration; get emergency
medical
attention and keep victim warm. Ingestion - Do
not induce vomiting. Get medical attention immediately. Waste
Disposal: Seal container when not in use. Empty containers must be
disposed in an approved landfill in accordance with local, state and
Federal regulations.
KEEP OUT OF REACH OF CHILDREN!
WARRANTY
We warrant our materials to be of good quality and will
replace materials found defective, providing, however, that the buyer
shall examine the materials when received and promptly notify us of any
defects before the materials are used or incorporated into a structure for
which they are intended. Unless otherwise agreed to in writing, this
warranty shall extend only to comply with specifications of materials
manufactured by and published by ALCO-NVC Inc., and made available to the
buyer at request. We cannot warrant nor in any way guarantee particular
methods, use or applications, nor can we warrant that the materials will
be suitable for any intended use. This warranty is in lieu of all others
expressed or implied and may not be extended by representatives, written
sales or information or drawings. Nor do our distributors or salesmen or
any other representatives of distributors or of this company have
any authority to extend any guarantee beyond that outlined above or to
waive the limitations of the seller's liability.
Give us a call at (800)
323-0029, we'll tell you even more!

ALCO-NVC Inc.
580
St. Jean Detroit, MI 48214-0001 Toll Free: (800)
323-0029 Fax: (313)
331-4726
HOME | ABOUT US |
PRODUCTS | SYSTEMS |
MSDS | CONTACT | REQUEST
© ALCO NVC, INC. ALL RIGHTS RESERVED. WEB SITE BY: DIVERSIFIED
COMPUTER SERVICES, INC.
|