DESCRIPTION ALCO MERIC White
Elastomeric Roof Coating is formulated using a 100% Acrylic Polymer base
that provides outstanding adhesion and superior reflectivity. It is
formulated to resist cracking and peeling from severe heat and cold.
USE : Excellent for coating metal, aged galvanized
repainted metal, urethane foam, concrete and other approved roof surfaces
ADVANTAGES
» Brilliant white color contributes significantly to reducing
interior temperatures by reflecting the sun's rays resulting in energy
savings » Forms rubber-like seal that moves and stretches
with normal expansion and contraction of roof surface
PREPARATION Surface to be coated must be free of oil, dirt
and debris. All loosely adhered material must be cut or scraped away.
Surface must be power washed then thoroughly rinsed, enabling good
adhesion to substrate. On metal roofs, all fasteners must be checked for
tightness. Badly rusted panels should be replaced. Slightly rusted areas
should be wire brushed and primed with ALCO Red Zinc Chromate Primer. New
metal roofs must be allowed to weather for a minimum of 6 months or acid
etched if time is essential. On concrete surfaces, be sure all cracks and
voids are repaired with a quality patching cement before coating.
APPLICATION For best results, apply with a soft brush,
roller or airless sprayer. Avoid excessive brushing. Apply at temperatures
above 50° F. One coat will normally cover any previous coating but two
coats are recommended,. This product has excellent suspension and requires
minimum stirring. If roof is hot, spray with water to prevent the coating
from drying too quickly. This material may be applied over damp, not wet,
surfaces. To obtain the additional strength of a "single-ply"
roof, apply a first coat and while coating is still wet or tacky, cover
with ALCO Poly-S Polyester Mat. Let dry, then apply second coat.
Apply only when coating will not be subjected to heavy dew or rain before
the coating has dried (approximately 5 hours).
CAUTION: If the coating is rained on or becomes wet before it is
thoroughly dry, there is a possibility that the material may dilute and
run off the roof onto other surfaces. Should this happen, clean the
stained surfaces as soon as possible with soap and water.
NOTE: Material may be used over aged (over 1 year) BUR and some modified
roof systems when ALCO Asphalt and Modified Bitumen Primer is used over
existing surface. For Polyurethane Foam, EPDM and aged CSPE-Hypalon™
Systems, see ALCO Reflective and Energy Saving Coatings manual.
FOR OUTDOOR USE ONLY
DO NOT THIN THIS PRODUCT
SECURE COVER WHEN NOT IN USE
COVERAGE Metal (Add for
Corrugation)
40 SF/Gallon
Smooth BUR/Modified
Bitumen
25 SF/Gallon
(2 Gal Primer; 2 Gal Coating)
Concrete
25 SF/Gallon
Polyurethane
Foam
25 - 30 SF/Gallon
PACKAGING 5 Gallon Pail
36/Pallet 55 Gallon Drum 4/Pallet
LIMITATIONS * For outdoor use only * For professional use only *
Do not use on wood * Do not thin this material *
May not be compatible with some one-ply systems. Check with manufacturer
before application * For use with EPDM, See ALCO Reflective
and Energy Saving Coatings brochure * PROTECT FROM FREEZING
PROPERTIES Vehicle Base:
100% Acrylic Resin
Weight per Gallon: 11.7 Lbs
Solids by Weight (ASTM 2369): 67 + 2%
Solids by Volume: 52 + 2%
Viscosity @ 77° F. (25° C.): 105 - 115 KU
Elongation: 300% @ 75° F. (24° C)
165% @ 0° F. (-18° C)
Tensile Strength @ 77° F. (25° C): 170 psi
Dry Film Thickness @ 1 Gal/100 [0.4075 L/Sq Meter]: 8.3 Mils
(Less absorption by surface)
Permeability (ASTM E-96): 5 perms
Dry Time:
Set to Touch: 1
Between Coats: 24 Hours Minimum
pH: 8.5 + 0.05
Specific Gravity: 1.141
Flash Point: None
Solvent: Water
Clean Up: Warm, soapy water
FOR FURTHER SAFETY INFORMATION
SEE MSDS REGARDING THIS PRODUCT
PRECAUTIONS
Contains Ethylene Glycol, Benzyl Phthalate Hazard Rating: Health
- 1 Fire - 0 Reactivity - 1
(0 = Least; 4 = Extreme) Respiratory:
Use with adequate ventilation. Inhalation of high vapor concentration may
cause headaches and/or dizziness. NIOSH/MSHA approved respirators required
if TLV is exceeded.
Personal Protection: Avoid prolonged or repeated
contact with skin, which may cause irritation. Wear chemical resistant gloves.
Do not get in eyes; wear protective goggles or face shield. Wear protective clothing if needed.
Do not take internally. Fire Protection: Keep away
from heat, open flame and any sources of ignition. First Aid: Eye Contact - Rinse
immediately with water for 15 minutes and seek medical
advice. Skin Contact - Wash with soap and water. Inhalation
- Remove individual to fresh air. If breathing is difficult, administer
oxygen. If breathing has stopped, give artificial respiration; get
emergency medical attention and keep victim warm. Ingestion - Do
not induce vomiting. Get medical attention immediately. Waste
Disposal: Seal container when not in use. Empty containers must be
disposed in an approved landfill in accordance with local, state and
Federal regulations.
KEEP OUT OF REACH OF CHILDREN!
WARRANTY
We warrant our materials to be of good quality and will
replace materials found defective, providing, however, that the buyer
shall examine the materials when received and promptly notify us of any
defects before the materials are used or incorporated into a structure for
which they are intended. Unless otherwise agreed to in writing, this
warranty shall extend only to comply with specifications of materials
manufactured by and published by ALCO-NVC Inc., and made available to the
buyer at request. We cannot warrant nor in any way guarantee particular
methods, use or applications, nor can we warrant that the materials will
be suitable for any intended use. This warranty is in lieu of all others
expressed or implied and may not be extended by representatives, written
sales or information or drawings. Nor do our distributors or salesmen or
any other representatives of distributors or of this company have
any authority to extend any guarantee beyond that outlined above or to
waive the limitations of the seller's liability.
Give us a call at (800)
323-0029, we'll tell you even more!

ALCO-NVC Inc.
580
St. Jean Detroit, MI 48214-0001 Toll Free: (800)
323-0029 Fax: (313)
331-4726
HOME | ABOUT US |
PRODUCTS | SYSTEMS |
MSDS | CONTACT | REQUEST
© ALCO NVC, INC. ALL RIGHTS RESERVED. WEB SITE BY: DIVERSIFIED